- Circuit Breakers[35]
- Doorbells[1]
- Relays[27]
- Contactors[19]
- Transformers[33]
- Voltage Regulators/Stabilizers[25]
- Capacitors[25]
- LED Lamps[6]
- MP3 Bags & Cases[2]
- Power Distribution Equipment[18]
- Time Switches[6]
- Timers[1]
- Switching Power Supply[27]
- Current Meters[26]
- Frequency Meters[1]
- Generator Parts & Accessories[2]
- Gasoline Generators[2]
- Diesel Generators[32]
- Energy Saving & Fluorescent[7]
- Other Lights & Lighting Products[7]
- Fuses[7]
- Uninterrupted Power Supply (UPS)[7]
- Pliers[4]
- Grinder[2]
- Other Power Tools[1]
- Other Wires[6]
- Cable Manufacturing Equipment[1]
- Contact Person : Mr. Adam John
- Company Name : Yueqing Open Imp.&Exp. Co., Ltd.
- Tel : 86-577-62739822
- Fax : 86-577-62738370
- Address : Zhejiang,Yueqing,Sulv Industrial Zone, Liushi, Yueqing City, Zhejiang Province. China
- Country/Region : China
- Zip : 325604
RXWO-35, RW10-35, RW9-35, RXWO-10 outdoor high voltage limit current fuse
RXWO-35, RW10-35, RW9-35, RXWO-10 outdoor high voltage limit current fuse.
1.Fuse pipe2.Porce lain sheath3.Support insulator4.Fastening flange5.Terminal cap
The structure and external dimension
The fuse is made up of fuse pipe,porcelain sheath,fastening flange,support insulator,terminal cap etc.separately fix up the terminal cap and fuse pipe in the porcelain sheath by the p ress way,then use the fastening flange to fix up the porcelain sheath on the support insulator.Refer to the chart for its structure and external dimension. The fuse pipe adopts the material wlth high content of oxide siIicon as the arc extinguishing media,and uses small-diameter metal Iine as fuse wi re.When the overload current or the short-circuit current passes the fuse pipe,the fuse wire immediately is broken,the electric arc occurs in a few paralIel-connection gaps,the metal steam in the electric arc inflltrates into the quartz sand,and it is Iiberated strongly,then quickly puts out the electric arc. Thus,this fuse has good performance and big b reaking capacity.
Installation and use
1.It is avallable to horizontal or verticalinstallation.2.Don’t connect the fuse when the data of fusearen’t accordant with the use viltage and rated current in the circuit.3.The users may take apart the terminal cap by themselves and replace the fuse with the same specification and performance, whenr the fuse pipe is broken.
Product type | Rated voltage | Rated current A | Capacity of largest blanking of three-phase | The Max breaking current | Weight | Note |
RXWO-35/0.5RXW10-35/0.5 | 35 | 0.2,0.5,1A | 1000 | 16 | 23 | protective voltage transformer |
RXWO-35/2RXW10-35/2 | 2 | 200 | 14 | Protect the power lines | ||
RXWO-35/3RXW10-35/3 | 3 | |||||
RXWO-35/5RXW10-35/5 | 5 | |||||
RXWO-35/7RXW10-35/7 | 7.5 | |||||
RXWO-35/10RXW10-35/10 | 10 |
Product type | Rated voltage | Rated current A | Capacity of largest blanking of three-phase | The Max breaking current | Weight | Note |
RXWO-(W)RXW10-(W) | 35 40.5 | 0.2,0.5,1A | 1000 | 16 | 26 | protective voltage transformer |
RXWO-(W)RXW10-(W) | 2 | 200 | 14 | Protect the power lines | ||
RXWO-(W)RXW10-(W) | 3 | |||||
RXWO-(W)RXW10-(W) | 5 | |||||
RXWO-(W)RXW10-(W) | 7.5 | |||||
RXWO-(W)RXW10-(W) | 10 |
RXWO-35, RW10-35, RW9-35, RXWO-10 outdoor high voltage limit current fuse