- Circuit Breakers[35]
- Doorbells[1]
- Relays[27]
- Contactors[19]
- Transformers[33]
- Voltage Regulators/Stabilizers[25]
- Capacitors[25]
- LED Lamps[6]
- MP3 Bags & Cases[2]
- Power Distribution Equipment[18]
- Time Switches[6]
- Timers[1]
- Switching Power Supply[27]
- Current Meters[26]
- Frequency Meters[1]
- Generator Parts & Accessories[2]
- Gasoline Generators[2]
- Diesel Generators[32]
- Energy Saving & Fluorescent[7]
- Other Lights & Lighting Products[7]
- Fuses[7]
- Uninterrupted Power Supply (UPS)[7]
- Pliers[4]
- Grinder[2]
- Other Power Tools[1]
- Other Wires[6]
- Cable Manufacturing Equipment[1]
- Contact Person : Mr. Adam John
- Company Name : Yueqing Open Imp.&Exp. Co., Ltd.
- Tel : 86-577-62739822
- Fax : 86-577-62738370
- Address : Zhejiang,Yueqing,Sulv Industrial Zone, Liushi, Yueqing City, Zhejiang Province. China
- Country/Region : China
- Zip : 325604
CD series Intelligent digital temperature controller
Detailed Product Description
CD series Intelligent digital temperature controller:
Iheating /Cooling control, Iauto adjusting function, Idigital communication, Ibig screen LED display, Iindustrial standard microcomputer processor
Model name:
Outline dimension | See the outline dimension picture | |
Control Mode | F:PID operation andauto calculating(reverse operation) | D:PID operation and auto calculating (Forward operation) |
W:hating/cooling PID operation and auto calculating (cooling water)*1 | A: hating/cooling PID operation and auto calculating (cooling water)*1 | |
Input mode | Refer to input Range Table | |
Range Code | Refer to input Range Table | |
First control output(OUT1) (Heating side) | M:Relay contact output V:Voltage impulse output T:Thyratron output | 8:Current output(IC4-20mA) G:Thyratron driving&triggering output |
Second control output(OUT2)(Cooling side)*2 | No mark:when the control mode is F or D M: Relay contact output V:Voltage impulse output | T:Thyratron output 8:Current output(IC4-20mA) |
First alarm (ALM1) Second alarmALM2 | Nno alarm A:Upper-limit bias alarm B:Lower-limit bias alarm C: Upper/Lower-limit bias alarm D:alarm in area E:Standby upper-limit bias alarm attached F: Standby lower-limit bias alarm attached G: Standby upper/lower-limit bias alarm attached H: Upper-limit input value alarm | J: Lower-limit input alarm K: Standby upper-limit input alarm attached L: Standby lower-limit input alarm attached P:Heater breakage alarm(CTL-6)*3 S: Heater breakage alarm(CTL-12)*3 R:Control line breakage alarm*4 V:Upper-limit set value alarm W:Lower-limit set value alarm |
Communication*5 | N:No communication | 5.RS-485(two-wire system) |
Water-proof/dust-proof | N:NO water-proof/dust-proof | 1:with water- proof/dust-proof |
*2 second alarm output (OUT2) Second alarm(ALM2)
*3 cant be set first alarm
*4 Control ring lie breakage can choose one only from alarm1 and alarm2
*5 Only CD series has the communication
Refer to Input Range Table
Thermocouple Input(TC) | Input type | Set range | Input type | Set range |
K | 0 to 1372(0 to 2502) | J | 0 to 1200(0 to 2192) | |
R | 0 to 1769(0 to 3216) | S | 0 to 1769(0 to 3216) | |
B | 0 to 1820(0 to 3308) | E | 0 to 1000(0 to 1832) | |
N | 0 to 1300(0 to 2372) | T | -199.9 to +400.0 (-199.9 to 752) | |
W5Re/W26Re | 0 to 2320(0 to 4208) | PL | 0 to 1390(0 to 2534) | |
L | 0 to 900(0 to 1652) | U | 0 to 900(0 to 1652) | |
RTD inputPt | 100Ω(JIS/IEC) | -199.9 to +649.0 (-199.9to 999.9) | JPT100Ω(JIS) | -199.9 to +600.0 (-199.9to 999.9) |
Voltage input | 0 to 5 VDC 1 to 5 VDC | -1999 to +9999 (programmable range) | ||
Current input | 0 to 20mADC 4 to 20mADC | -1999 to +9999 (programmable range) |